191.  Sometimes refrigeration plants use cooling towers. The water cooled in those towers is supplied
A. For defrosting evaporator coils B. To cool compressor cylinder only
C. To cool refrigerant in evaporator D. To cool refrigerant in condenser
E. None of the above    

192.  During air conditioning whenever two or more streams of moist air are mixed they follow
A. Adiabatic process B. Isothermal process
C. Polytropic process D. Constant pressure process
E. Polytropic process    

193.  For a sensible heating the air is passed over a heating coil which may be
A. Heated by electric resistance B. Heated by passing hot water through the coil
C. Heated by passing steam through the coil D. Heated by direct solar radiations
E. Heated by any of the above methods    

194.  When moisture is removed from air at constant dry bulb temperature the process is known as
A. Aeration B. Deionisation
C. Dehumidification D. Drying
E. Sensible cooling    

195.  When moisture is added to air at constant dry bulb temperature, the process is known as
A. Humidification B. Sensible cooling
C. Wetting D. Chilling
E. None of the above    

196.  In case air is cooled by a process in which the humidity ratio of air does not change, the process is known as
A. Humidification B. Dehumidification
C. Ventilation D. Chilling
E. Sensible cooling    

197.  Which of the following are synonyms?
A. Humidity ratio and specific humidity B. Degree of saturation and degree of reaction
C. Sensible cooling and dehumidification D. Relative humidity and specific humidity
E. Dehumidification    

198.  The ratio of mass of water vapour associated with unit mass of dry air to the mass of water vapour associated with unit mass of dry air saturated at the same temperature is known as
A. Relative humidity B. Specific humidity decreases
C. Humidity ratio D. Degree of saturation
E. None of the above    

199.  The condension of moisture contained in air will take place at
A. Dry bulb temperature B. Wet bulb temperature
C. Any where between dry bulb temperature and wet bulb temperature D. Saturation temperature
E. Dew point temperature    

200.  The ratio of sensible heat to total heat is known as
A. Dew point B. Humidification ratio
C. Relative humidity D. Specific humidity
E. Sensible heat factor    




© 2012-2024 by GeekMCQ™ Technologies. All Rights Reserved | Copyright | Terms of Use & Privacy Policy

Contact us: info@geekmcq.com